Pitot Tube Anemometer PCE-HVAC 2
For flow velocities up to 80 m/s (178.66 mph); also determines differential pressure, flow rate, temperature; with data storage; Software for real-time transmission included
The PCE-HVAC-2 is a pitot tube anemometer for measuring differential pressure, airflow, air velocity and temperature. Due to its design, the anemometer equipped with an angled pitot tube, is particularly suitable for the rapid and precise determination of high air velocities of up to 80 m / s. During the measurement of the flow velocity, this pitot tube anemometer offers a choice of units (m / s, knots, km / h, mph, ft / min).
The 33.5-cm long pitot tube with a diameter of only eight millimetres, attached to the pitot tube anemometer, makes the application in confined work spaces, small openings and pipe systems possible. The manufacturer has equipped the meter with some practical features, which makes its application versatile. So that it could be mounted on a tripod, the pitot tube anemometer has a thread on the bottom side. Thus, in this position, the user has two free hands which provides a much better flexibility in the handling of the pitot tube.
The supplied two pressure hoses, each 85 centimetres long, are attached to the top of the pitot tube anemometer and then can be connected to the L-shaped pitot tube.
Air pressure | |
Accuracy | ± 0.3% of reading at 25°C / 77°F |
Repeatability | ± 0.2% (± 0.5% of reading) |
Linearity / hysteresis | ± 0.29% of reading |
Pressure range | 5000 Pa |
Maximum pressure | 10 psi |
Response time | Typically 0.5 seconds |
Measuring range | 0.7252 psi 50.00 mbar 20.07 inH2O 509.8 mmH2O 5000 Pa |
Resolution | 0.0001 psi 0.01 mbar 0.01 inH2O 0.1 mmH2O 1 Pa |
Selectable units | Mbar, psi, inH2O, mmH2O, or Pa |
Air speed | |
Measuring range | 1 ... 80 m / s 200 ... 15733 ft / min 3.6 ... 288 km / h 2.24 ... 178.66 MPH 2 ... 154.6 knots |
Resolution | 0.01 m / s 1 ft / min 0.1 km / h 0.01 MPH 0.1 knots |
Accuracy | At m / s: ± 2.5% of measured value At ft / min, Km / h, MPH and Node: Depending on the air speed and the size of the air duct |
Flow rate | |
Measuring range | 0 ... 99999 m³ / min 0 ... 99999 ft³ / min |
Resolution | 0.001 ... 100 m³ / min 0.0001 ... 100 ft³ / min |
Temperature | |
Measuring range | 0 ... 50°C / 32 ... 122°F |
Resolution | 0.1°C / 0.18°F |
Accuracy | ± 1°C / ± 1.8°F |
General | |
Diameter of pitot tube | 8 mm / 0.3 in |
Length of measuring hoses | Each 85 cm / 33.46 in |
Total length of the tube | 335 mm / 13.18 in |
Low battery indicator | Yes |
Power supply | 9V block battery |
Operating conditions | 0 ... 50°C / 32 ... 122°F / <90% RH non-condensing |
Storage conditions | -10 ... 60°C / 14 ... 140°F / <90% RH non-condensing |
Internal memory | 99 measured values per parameter |
Interface | USB |
Display | LCD |
Housing material | ABS plastic |
Dimensions | Device: 206 x 95 x 45 mm / 8.11 x 3.7 x 1.7 in Pitot tube: 335 mm / 13.18 in - Ø 8 mm / 0.31 in |
Weight (incl. pitot tube, battery and measuring hoses) | 600 g / 1.3 lbs |
SR-305 is a pitot tube used to determine the directional airflow velocity in ventilation ducts using differential pressure. Suitable for the measurement of dynamic pressure of gaseous media in flow-restricted line sections. Prandtl tube (i.e., pitot-static tube) with elliptical head shape for high accuracy.
- Pipe length: 300 mm / 11.81"
- Pipe diameter: 4 mm / 0.16"
- Head length: 65 mm / 2.56"
- Head diameter: 4 mm / 0.16"
- Connection: Plug for connecting to measuring hoses
- Material: Stainless steel
SR-483 is a pitot tube used to determine the directional airflow velocity in ventilation ducts using differential pressure. Suitable for the measurement of dynamic pressure of gaseous media in flow-restricted line sections. Prandtl tube (i.e., pitot-static tube) with elliptical head shape for high accuracy.
- Pipe length: 483 mm / 19.02"
- Pipe diameter: 8 mm / 0.32"
- Head length: 130 mm / 5.12"
- Head diameter: 8 mm / 0.32"
- Connection: Plug for connecting to measuring hoses
- Material: Stainless steel
SR-795 is a pitot tube used to determine the directional airflow velocity in ventilation ducts using differential pressure. Suitable for the measurement of dynamic pressure of gaseous media in flow-restricted line sections. Prandtl tube (i.e., pitot-static tube) with elliptical head shape for high accuracy.
- Pipe length: 795 mm / 31.30"
- Pipe diameter: 8 mm / 0.32"
- Head length: 130 mm / 5.12"
- Head diameter: 8 mm / 0.32"
- Connection: Plug for connecting to measuring hoses
- Material: Stainless steel