Nile Radar Sensor
Designed for non-contact water level measurement, the WaterLOG Nile Series (502/504/517) combines high accuracy with an out-of-the-box measurement range of up to 70 m. Its reliable interface and simple SDI-12 communication ensure seamless integration with current water monitoring stations. With three models to choose from, the Nile Series is sure to meet your water monitoring needs.
Connectivity / Communications | SDI-12, RS-232 |
---|---|
Material | PBT Plastic (Housing); PP Cladded (502, 504 Cone), 316L (517 Cone) |
Operating Temperature | -40° C to + 60° C |
Power | Voltage Input: 10 to 16 VDC | Supply Current: Active: <13.5 mA |
Size | Housing: 168 mm (6.61 in) x 144 mm (5.67 in) |
Storage Temperature | -40° C to + 60° C |
Warranty | The Nile series radars are warranted against defects in materials and workmanship for two years from date of shipment. |
Weight | 2.7 kg (502, 504); 4.2 kg (517) |
Physical | Nile 502 | Nile 504 | Nile 517 |
---|---|---|---|
Size (Horn) | 80 mm (3.15 in), 115 mm (4.53 in) x 137.9 mm (5.43 in) | 100 mm (3.94 in), 135 mm (5.31 in) x 150.5 mm (5.93 in) | 100 mm (3.94 in), 95 mm (3.74 in) x 282mm (11.10 in) |
Performance | Nile 502 | Nile 504 | Nile 517 |
---|---|---|---|
Range | 1 to 20 m (3 to 66 ft) | 2 to 40 m (7 to 131 ft) | 2 to 70 m (7 to 230 ft) |
Standard Accuracy* | ±2 mm (0.08 in) over range of 1.06 to 20 m (3.5 to 66 ft) | ±3 mm (±0.1 in) over range of 2.1m to 40 m (7.0 to 131 ft) | ±3 mm (±0.1 in) over range of 2.1m to 70 m (7.0 to 2309 ft) |
Near Target Accuracy | ±5 mm (±0.2 in) over range of 0 to 1.06 m (0 to 3.5 ft) | ±21 mm (±0.8 in) over range of 0 to 2.1 m (0 to 7.0 ft) | ±21 mm (±0.8 in) over range of 0 to 2.1 m (0 to 7.0 ft) |
Temperature Error (Limited Temperature Change) | ±2 mm (±0.08 in) max error per 10°C change | ±5 mm (±0.2 in) max error per 10°C change | ±5 mm (±0.2 in) max error per 10°C change |
Temperature Error Max | ±5 mm (±0.2 in) max error from -40° C to 60° C | ±15 mm (±0.6 in) max error from -40° C to 60° C | ±15 mm (±0.6 in) max error from -40° C to 60° C |
Frequency | ~26 GHz | ~26 GHz | ~26 GHz |
Transmitting Power | <0.4 nW/cm2 | <2.5 nW/cm2 | <2.5 nW/cm2 |
Maximum Measurement Error on Low End | ±4.0 mm (<1 m) 0.16 in (<3.28 ft) | ±20.0 mm (<2 m) 0.78 in (<6.56 ft) | ±20.0 mm (<2 m) 0.78 in (<6.56 ft) |
Beam Angle | 10° | 8° | 8° |
Measurement Distance | Nile 502 Beam Width | Nile 504 Beam Width | Nile 517 Beam Width |
---|---|---|---|
3 m (9.84 ft) | 0.53 m (1.74 ft) | 0.42 m (1.38 ft) | 0.42 m (1.38 ft) |
6 m (19.69 ft) | 1.05 m (3.45 ft) | 0.84 m (2.76 ft) | 0.84 m (2.76 ft) |
9 m (29.53 ft) | 1.58 m (5.18 ft) | 1.26 m (4.13 ft) | 1.26 m (4.13 ft) |
12 m (39.37 ft) | 2.10 m (6.89 ft) | 1.68 m (5.51 ft) | 1.68 m (5.51 ft) |
15 m (49.22 ft) | 2.63 m (8.63 ft) | 2.10 m (6.89 ft) | 2.10 m (6.89 ft) |
20 m (65.62 ft) | 3.50 m (11.48 ft) | 2.80 m (9.19 ft) | 2.80 m (9.19 ft) |
25 m (82.03 ft) | 3.50 m (11.48 ft) | 3.50 m (11.48 ft) | |
30 m (98.43 ft) | 4.20 m (13.78 ft) | 4.20 m (13.78 ft) | |
35 m (114.84 ft) | 4.89 m (16.04 ft) | 4.89 m (16.04 ft) | |
40 m (131.24 ft) | 5.59 m (18.34 ft) | 5.59 m (18.34 ft) | |
45 m (147.65 ft) | 6.29 m (20.64 ft) | ||
60 m (196.86 ft) | 8.39 m (27.53 ft) | ||
70 m (229.67 ft) | 9.79 m (32.12 ft) |
*Accuracy was determined under the following reference conditions: +24°C±5°C, 960 mbar abs., 60% ± 15% RH, using a metal plate reflector with a minimum diameter of 1 m, in accordance with EN 61298-3.