Infrared Thermometer PCE-675-ICA Incl. ISO Calibration Certificate incl. Type K
Infrared Thermometer PCE-675-ICA incl. ISO calibration certificate Easy-to-use infrared thermometer with red laser pointer / Measuring input for K-type / Surface temperatures / Air temperature / Humidity / Dew point temperature
The infrared thermometer has a 13:1 spot-to-spot ratio and can accurately measure surface temperatures and ambient humidity over a very long distance. The infrared thermometer brings advantages, such as a simple operation and a red sighting laser. These features allow the near-perfect alignment of the infrared thermometer for accurate measurements. The infrared thermometer is universally applicable. The integrated flashlight allows the measuring point to be illuminated in the dark. The individual settings of the infrared thermometer allow a wide range of temperatures and humidity to be measured. The infrared thermometer does not have a fixed emission value, but has a set span of 0.1 to 1.0, thus covering more than 90% of all temperature measurement tasks.
- Low measurement sequence
- Emissivity adjustable between 0.1 and 1.0
- Automatic shutdown
- Switchable laser sighting aid
- Measured value display selectable between °C and °F
- Different exhibition settings
- Battery operation
- Compact and robust design
- Incl. ISO calibration certificate
Measuring function | Infrared |
Measuring range | -50 ... 550 °C |
Resolution | ≤ 1000 °C/°F: 0.1 °C/°F |
> 1000 °C/°F: 1 °C/°F | |
Accuracy | -50 … 0 ºC: ± 3 ºC |
> 0º C: ± 1.5 % or ± 2.0 | |
the larger value counts | |
Measuring function | Type K |
Measuring range | -50 … 850 ºC |
Resolution | ≤ 1000 °C/°F: 0.1 °C/°F |
> 1000 °C/°F: 1 °C/°F | |
Accuracy | ± 1.5 % or ± 1.5 °C |
the larger value counts | |
Measuring function | Air temperature |
Measuring range | -20 … 60 ºC |
Resolution | 0.1 °C |
Accuracy | 0 … 40 ºC: ± 1.0 ºC |
Other: ± 2 °C | |
Measuring function | Humidity |
Measuring range | 0 … 100 % r.H. |
Resolution | 1 % |
Accuracy | 35 … 75 % r.H.: |
± 3.0 % r.H. | |
Other: ± 5 % r.H. | |
Measuring function | Dew point |
Measuring range | -20 … 60 ºC |
Resolution | 0.1 °C |
Accuracy | 25 ºC, 40 … 80 % r.H.: ± 1.5 ºC |
Wet bulb temp. | |
Measuring range | -20 … 60ºC |
Resolution | 0.1 °C |
Accuracy | 25 °C: ± 1.5 °C |
Emissivity | adjustable between 0.1 and 1.0 |
Optical resolution | 13 : 1 |
Response time | ≤ 500 ms |
Spectral sensitivity | 8 … 14 um |
Laser | ≤ 1 mW, 630 … 670 nm, class 2 laser |
Automatic shutdown | after one minute |
Operating conditions | 0 … 50 ºC / ≤ 95% r.H. |
Storage conditions | -20 … 70 ºC / ≤ 80 % r.H. |
Power supply | 9 V battery |