Noise Dosimeter ST - 130
• Perform OSHA and IEC noise accumulation surveys
• 6 built-in standard dose measurement setups: OSHA/ MSHA/DOD/ACGIH/ISO85/ISO90
• Data logger up to 10,00,000 readings
• Adjustable criterion level, exchange rate & threshold
• Sampling times between 1 sec to 2 hr
• Dose Meter Mode: record time stamp, %Dose, TWA8, LEP, 8h, Leq, SEL, LN%, SPLmax, SPLmin, PeakMAX
• Sound Level Meter mode: Leq, PeakMAX & SEL
The Scarlet ST-130 Noise Dosimeter is the ideal tool to carry out occupational and industrial hygiene noise measurements and provide a unique solution for these applications. ST-130 is designed to meet the standard dose measurement of OHSA, IEC and ISO regulations. To measure long-term noise exposure, the ST-130 comes with small, lightweight, cable-free designs and can be worn on the shoulder for minimal inconvenience.
Application:
• Evaluation of environmental noise and logging
• Measurements of occupational noise at workplaces
• Compliance with noise at Work Regulations and occupational noise exposure guidelines
• Monitoring and recording of long term noise exposure
• Noise exposure measurements in hazardous environments such as oil fields, petrochemical plants and underground mines
• Measurement of noise exposure in the entertainment and music industries
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
A Dosimeter is an instrument used to measure noise in a workplace and is usually worn by workers as a safety precaution. Dosimeters are available in a range of price points, depending on the complexity of the device and its number of features. The most basic dosimeter can cost as little as $150, while units with more advanced feature sets can be priced at over $500. Key features to look for in a dosimeter include the type of sound measurement being made (e.g., peak levels or average levels), the frequency range of measurement, and the accuracy of the device.
It is important to note that some dosimeters may need to be calibrated each year as part of their required maintenance. This process can add to the overall cost of ownership, so it is important to factor in any additional fees when considering the price of a dosimeter.
The more sophisticated a dosimeter, the higher its cost due to the advanced features it offers. Other factors affecting dosimeter prices include brand reputation, availability of components used in manufacturing, accuracy rating and calibration process.
For example, the more features a dosimeter provides, such as noise level measurement over multiple frequency ranges, the higher its price. Similarly, if the device's components are in short supply and difficult to obtain, it drives up prices significantly. Accuracy ratings also impact pricing; models with higher accuracy ratings tend to cost more than lower-rated ones. Finally, calibration costs can affect the dosimeter's price tag.
Our dosimeters are designed with utmost precision and tested under rigorous conditions, so you can trust us to help you measure sound levels accurately in any situation. Our range of products offers features to suit different needs, and our knowledgeable staff is always available to answer any questions you may have about dosimeter price and performance.
When it comes to industrial measurement tools, the dosimeter is a crucial instrument. It measures sound levels in noisy environments and ensures that noise levels remain within legal limits. Therefore, the dosimeter price can vary depending on its features and capabilities.
For example, advanced dosimeters include features such as adjustable thresholds, data logging, multiple memory locations for storing data, and the ability to measure a range of noise levels. These features are usually supported by more sophisticated hardware and software, which can push up the price of these instruments.
Similarly, some dosimeters may be designed specifically for industrial or military use, in which case they will include additional features such as integration with other systems and specialized components that enable them to withstand extreme temperature and shock. This makes them more expensive than standard models.
At ADK Instruments, we understand that price is an important factor when it comes to selecting the right dosimeter for your industrial application. That's why we offer a range of dosimeters with different features and prices, so you are sure to find one that meets your needs. Our experienced team is ready to provide professional advice and assistance in selecting the most suitable dosimeter for your application.
A dosimeter plays a crucial role in radiation protection and safety measures, primarily used to monitor and measure individuals' exposure to ionizing radiation. This device's importance lies in its ability to provide real-time data on radiation dose, allowing for immediate action if exposure levels exceed safety thresholds. The dosimeter price varies depending upon a range of factors such as type, functionality, brand, and sophistication level. Despite the cost, the assurance of health and safety that dosimeters provide in environments with potential radiation exposure is invaluable. They are used across a variety of fields, including healthcare, nuclear power generation, and scientific research. This diverse application spectrum further underscores the dosimeter's unique importance in maintaining safety standards and regulating radiation exposure.
The dosimeter's range is dictated by its design and purpose, varying significantly across different models. Typically, it can measure radiation doses from as low as a few microsieverts to as high as several sieverts. The specific range of a dosimeter is vital as it determines the environments in which it can be effectively used. For instance, a dosimeter designed for high-radiation environments like nuclear power plants may not be suitable for lower-radiation settings such as medical facilities.
When considering the dosimeter price, potential buyers must also factor in the device's range, ensuring it aligns with their specific monitoring requirements. The right balance between cost and functionality will ensure effective radiation safety management.
There are primarily two types of dosimeters: active and passive.
Active dosimeters also referred to as electronic dosimeters, provide real-time information about the amount of radiation exposure. They are typically used in environments where radiation levels may change rapidly, such as nuclear power facilities. Despite their higher dosimeter price point, the immediate feedback they offer on radiation levels makes them an essential tool for those working in high-risk environments.
Passive dosimeters, on the other hand, do not provide real-time data. Instead, they store information about radiation exposure over a period of time, which is analyzed later. These devices are commonly used in lower-risk settings such as hospitals, dental offices, and research labs. While they may have a lower initial dosimeter price, the cost of periodic analysis can add up over time.
In conclusion, when considering the dosimeter price, it's important to also consider the type of dosimeter and its corresponding functionality to ensure it aligns with the specific radiation monitoring needs.
Item | Description |
Measurement items (Noise Dosimeter) | Does%, Lxyp, Lxmax, Lxmin, Lxeq, SEL( LAE ), PeakMAX, LAVG, TWA, LEP, LN% |
Measurement items (sound level meter) | Lxyp, Lxmax, Lxmin, Lxeq, SEL( LAE ), PeakMAX |
Display range | 30...90 dB (L), 50...110 dB (M), 70...140 dB (H) |
Primary RMS range @ 1 kHz | 41...86 dB (L), 55...106 dB (M), 75...125 dB (H) |
Max Cpeak measurement | 90...143 dB |
Dynamics range | 60 dB |
Accuracy | +/- 1.4 dB @ 94 dB / 1 kHz |
Microphone (ST-130S) | 1/2” pre-polarized condenser microphone build in preamplifier: 1V/Pa@250HZ, frequency range: 20 Hz~12.5 kHz, Thermal noise: < 25 dB(A) |
Display | Single LCD MAX reading 999999 |
Display refresh rate | 1 Hz |
Internal memory | Data loger data: 10,000 NDM surveys; 1,000,000 SLM readings |
Time weighting | Fast / Slow / Impulse |
Frequency weighting | A /C /Z |
Frequency range | 20 Hz...8 kHz |
Starting time | Less than 10 sec |
Battery life ( ST-130 ) | 24 hours ( 9V Alkaline battery x 1 ) |
Dimensions | 107 (L) x 65 (W) x 33 (H) mm |