Air Quality Meter PCE-EM 880
The air quality meter is equipped with various sensors to determine HCHO, TVOC, ambient temperature and ambient humidity. This means that the air quality meter already covers a wide range of measurement tasks. The measuring range for the TVOC measurement is 0.00 … 9.99 mg/m³. With an accuracy of ±5% of the measuring range for HCHO and TVOC measurement, the air quality meter is the ideal measuring tool for indicative measurements.
Thanks to the built-in 1500 mAh battery, it is possible to operate the air quality meter as a mobile device. As soon as the battery is discharged, it can be recharged via the micro USB interface with a 5 V DC power supply.
The air quality meter is therefore used, for example, to check the air quality in offices, workshops, school facilities or in logistics to check the premises for volatile organic substances and formaldehyde.
The readings are stored directly on the air quality meter. A memory with 5000 measuring points is available for the air quality meter. After a measurement, the readings can be analyzed on the air quality meter. In addition, the readings from the air quality meter can be transferred to a PC. When connecting the air quality meter to a PC, the air quality meter is recognized as a mass data storage device. This has the particular advantage that the air quality meter works independently of the operating system. The measured values are saved in CSV file format by the air quality meter.
Memory for 5000 measuring points
HCHO | |
Measuring range | 0.00 … 5.00 mg/m³ |
Resolution | 0.01 mg/m³ |
Accuracy | ±5 % of measuring range |
TVOC | |
Measuring range | 0.00 … 9.99 mg/m³ |
Resolution | 0.01 mg/m³ |
Accuracy | ±5 % of measuring range |
Temperature | |
Measuring range | 0 … 50 °C / 32 … 122 °F |
Resolution | 0.1 °C / 0.1 °F |
Accuracy | ±2 °C / ±4 °F |
Humidity | |
Measuring range | 0 … 100 % RH |
Resolution | 0.1 % RH |
Accuracy | ±3.5 % at (20 … 80 % RH) |
±5 % at (0 … 20 %) | |
±5 % at (80 … 100 %) | |
Further specifications | |
Memory space | for 5000 measuring points |
File format | CSV |
Memory rate | 1 minute, 15 minutes, 1 hour |
Warm-up time | HCHO: 10 seconds |
TVOC: 90 seconds | |
Units | |
Temperature | °C, °F |
HCHO / TVOC | ppm, mg/m3 |
Measuring rate | 1 Hz |
Alarm | visual |
Interface | Micro USB interface |
Power supply (battery) | 3.7 V, 1500 mAh |
Power supply (power pack) | 5 V DC, 1 A |
Operating conditions | 0 … 45 °C / 32 … 113 °F, <90 % RH |
Storage conditions | -10 … 55 °C / 14 … 131 °F, <90 % RH |
Dimensions | 54 x 215 x 34 mm / 2.1 x 8.4 x 1.3" |
Weight | 143 g / 5.0 oz |
1 x Air quality meter PCE-EM 880
1 x Micro USB cable
1 x Instruction manual